COMMERCIAL TANK SPECIFICATIONS
If you have any further questions on the information on this page, fill out the form below and we will get back to you.
Tank Wall and Roof Sheets | |||
---|---|---|---|
Sr. No. | Parameter | Description | |
1 | Type | Steel Bolted Liner Tanks | |
2 | Shape | Cylindrical | |
3 | Wind Bearing Empty Design | Acording to AS/NZ1170 | |
4 | Type of Steel | Zincalume® or Colorbond® or Colorbond Ultra® Bluescope Steel | |
5 | Wall Steel Grade | G300 8-80 V LOCK Corrugation Bluescope Steel | |
6 | Wall Thickness | Minimum 0.8mm 8-80 V LOCK Corrugation | |
7 | Roof Steel Grade | G550 Custom Orb Bluescope Steel | |
8 | Roof Type and Truss | Dome Roof - Self supporting structure style. Square hollow section HDG to suit AS/NZS1170 Standards with swivel truss foot. | |
9 | Roof Sheets Thickness | 0.42 to 0.48 BMT | |
10 | Truss Coating | Hot dip galvanised as per AS4680 | |
11 | Document Requirements | Full technical package including design and load calculations including drawings | |
12 | Applicable Design Standards | Australian and New Zealand Standards | |
| |||
| |||
| |||
| |||
| |||
| |||
Tank Liner | |||
Sr. No | Parameter | Description | |
20 | Liner Make | As recommended by manufacturer | |
21 | Thickness | As recommended by manufacturer | |
22 | Tensile Strength Standard | (AS 2001.2.3.1-2001) | |
23 | Wing Rip Standard | (AS 2001.2.10-1986) | |
24 | Water Portability Standard | AS/NZS 4020:2005 | |
25 | Flex Cracking Resistance | As recommended by manufacturer | |
26 | Temperature | As recommended by manufacturer | |
Tank Accessories | |||
Sr. No | Parameter | Description | |
27 | Ladders | Fixed ladders inside/outside - hot dip galvanised. Outside ladder with cage. | |
28 | Access Hatch | Standard hinged access hatch or commercial type heavy duty with handrails and SS hinges | |
29 | Nozzles | HDPE or galvanised | |
30 | Level Indicator | Mechanical heavy duty bolted to concrete ring beam | |
31 | Air Vent |
| |
32 | Cathodic Protection | Magnesium Anodes | |
33 | Geotextile | Non-vowen, needle punched as per 175 marv grams per sq mt as per test standardas 3706.1 mass (property) | |
34 | Condensation Strips | As per manufacturers specifications | |
35 | Dust Proofing | As per manufacturers specifications | |
36 | Circular Hoops and Brackets | Load calculated hold down brackets. Hot dip galvanised top and bottom hoops | |
37 | Corrosion Protection | Epoxy coating - Optional as per manufacturers recommendations | |